Beijer

Beijer X2 base 7 - F2 I/O00A (First Version From 2016)

7'' HMI with iX runtime and IOs

  • 800 × 480 pixel (16:9) TFT-LCD touch screen
  • Built-in digital and analog IOs
  • 200 MB application memory
  • 1 × Ethernet, 4 × serial, 1 × USB as standard
  • Operating temperature -10° to +50° C
  • CE, FCC


Facts

General description
Part number 630020105
Life cycle status Mature
Warranty Up to 2 years
Certifications
General CE, FCC
Mechanical
Mechanical size

196 x 146 x 84mm

Panel Mount

1million finger touch operations

Touch type Resistive
Cut-out size 186 x 136mm
Weight 0,9 kg
Housing material Plastic (PC+ABS), Gray
Buzzer Yes
LED Yes
Power
Input voltage 24 V DC (18 to 32 VDC)CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supplymust conformwith the requirements for class II power supplies.
Power consumption (max)

9.6W

Input fuse Internal DC fuse
Hardware platform X2 base
CPU ARM9 400 MHz
RAM 128 MB
FLASH 256 MB, 200 MB free
Display
Size diagonal 7" diagonal
Resolution 800x480 pixels
Backlight LED Backlight
Backlight life time 20000 hours
Backlight brightness 400 cd/m2
Backlight dimming Industrial Dimming
Display type TFT-LCD with LED backlight
Digtal IO
Digital input 8 inputs, 24 VDC at 5.6mA (0.13W per input)
Cofiguration 2 isolated, independent groups with 4 inputs per group. Each group shares one common contact. Supports sink/source mode for each group.
Type IEC 61132-2 Type I
Isolation 550 VAC, 1min
Digital output 6 outputs, 30 VDC, 3A max
Configuration 3 isolated, independent groups with 2 outputs per group. Each group shares one common contact.
Type Relays (contact configuration: SPST-NO)
Isolation 550 VAC, 1min
Analog IO
Analog input channels

4

Input type 0-10V or 4-20mA
Input impedance According to EN 61131-2
Galvanic isolation

No

Resolution 14 Bit (0-10V: 0…16383 / 4-20mA: 3277…16383)
Conversion time 100ms per channel
Accuracy 0.3%
Analog output channels

2

Output type 0-10V or 4-20mA
Output impedance According to EN 61131-2
Galvanic isolation

No

Resolution 14 Bit (0-10V: 0…16383/4-20mA: 3277…16383)
Conversion time 100ms
Accuracy 0.3%
Serial communication
Number of serial ports 2 Port 9pin DSUB
Serial port 1 RS 232 (RTS/CTS)
Serial port 2 RS422/485
Serial port 3 RS 232
Serial port 4 RS 485
Ethernet communication
Number of Ethernet ports

1

Ethernet port 1 1x10/100 Base-T (shielded RJ45)
Expansion interface
Expansion port No
SD card

No

USB 1xUSB 2.0 400mA
Environmental
Operating temperature -10°C to +50°C
Storage temperature -20° to +60°C
Shock 15g, half-sine, 11ms according to IEC60068-2-27
Vibration 1g, according to IEC 60068-2-6, Test Fc
Sealing front IP65
Sealing back IP20
Humidity 5% – 85% non-condensed
Doküman Adı

Dil

CAB103_10m
CAB103_15m
CAB103_3m
CAB100 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
CAB101 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
CAB104 Cable Drawing forX2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
CAB105 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
CAB106 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
CAB107, 25-pol to 9-pol adapter, Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
CAB108 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel
CAB109 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel
CAB110 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel
AB150 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel
Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI
Doküman Adı

Dil

TxA, X2 base image 1.12 b1335 (Current version)
TxA, X2 base image 1.12 b1335 (Current version) (PIEN281H)
TxA, X2 base image 1.12 b1335 (Current version) (PIEN284H)
Doküman Adı

Dil

Battery test summary - X2 base, Y2 base v2, BoX2 base v2, C2 industrial PCs
Environmental Report X2 base
X2 export control and dual use
X2 Letter of Volatility
Input regarding unsuported Drivers for X2 base (v1)/BoX2 base (v1)
Guidelines for TxA and TxB migration to X2.
Doküman Adı

Dil

16--TtM_beijer_electronics_life_cycle_notification--X2 base and X2 base ADP
17--TtL_beijer_electronics_life_cycle_notification--X2-base_image_ADP
Doküman Adı

Dil

iX Developer SP7 - 2.47.473 Release information (LastMinuteNotes iX PIEN341L)
iX Developer SP7 - 2.47.473 Release information (ReleaseNotes iX PIEN340Q)
Best Practice Database on SD card or flash memory
How to download Free software packages from SmartStore
iX - SMTP - Using Gmail servers using App password
Quick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411
Doküman Adı

Dil

X2 base 10_Verification FCC
X2 base 5_Verification FCC
X2 base 7_Verification FCC
X2 base 10 – F2_CE Verification
X2 base 5 - F2_CE Verification
X2 base 7 – F2_CE Verification.pdf
X2 base 10 KCC MSIP Certificate
X2 base 10 KCC Permissive letter
X2 base 5 KCC MSIP Certificate
X2 base 5 KCC Permissive letter
X2 base 7 KCC MSIP Certificate
X2 base 7 KCC Permissive letter.pdf
DoC battery X2 base (V2)
DoC ECCN for X2 series HMI
Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion
RoHS and REACH Declaration of Conformity
UL E192000 for X2Base ,TxA, Exter
X2 base DoC CE ROHS
SDoC Green Passport
Doküman Adı

Dil

Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3.
Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3.
Program example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3.
Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414
Quick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406
Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405
Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403
Doküman Adı

Dil

iX Developer Reference Manual, MAEN355 rev. B (current version)
Doküman Adı

Dil

Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels
SqlProxy - Connects iX Panels transparently to SQL Server (161202C)
SqlProxy - Connects iX Panels transparently to SQL Server (190115)
SqlProxy - Connects iX Panels transparently to SQL Server (191016C)
SqlProxy - Connects iX Panels transparently to SQL Server (170330)
Doküman Adı

Dil

X2 brochure (English), BREN631
X2 brochure (Spanish)​
X2 brochure 2019 (French)
X2 series (German)