Beijer X2 base 7 - F2 I/O00A (First Version From 2016)
7'' HMI with iX runtime and IOs
- 800 × 480 pixel (16:9) TFT-LCD touch screen
- Built-in digital and analog IOs
- 200 MB application memory
- 1 × Ethernet, 4 × serial, 1 × USB as standard
- Operating temperature -10° to +50° C
- CE, FCC
Facts
| General description | |
|---|---|
| Part number | 630020105 |
| Life cycle status | Mature |
| Warranty | Up to 2 years |
| Certifications | |
| General | CE, FCC |
| Mechanical | |
| Mechanical size |
196 x 146 x 84mm Panel Mount 1million finger touch operations |
| Touch type | Resistive |
| Cut-out size | 186 x 136mm |
| Weight | 0,9 kg |
| Housing material | Plastic (PC+ABS), Gray |
| Buzzer | Yes |
| LED | Yes |
| Power | |
| Input voltage | 24 V DC (18 to 32 VDC)CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supplymust conformwith the requirements for class II power supplies. |
| Power consumption (max) |
9.6W |
| Input fuse | Internal DC fuse |
| Hardware platform | X2 base |
| CPU | ARM9 400 MHz |
| RAM | 128 MB |
| FLASH | 256 MB, 200 MB free |
| Display | |
| Size diagonal | 7" diagonal |
| Resolution | 800x480 pixels |
| Backlight | LED Backlight |
| Backlight life time | 20000 hours |
| Backlight brightness | 400 cd/m2 |
| Backlight dimming | Industrial Dimming |
| Display type | TFT-LCD with LED backlight |
| Digtal IO | |
| Digital input | 8 inputs, 24 VDC at 5.6mA (0.13W per input) |
| Cofiguration | 2 isolated, independent groups with 4 inputs per group. Each group shares one common contact. Supports sink/source mode for each group. |
| Type | IEC 61132-2 Type I |
| Isolation | 550 VAC, 1min |
| Digital output | 6 outputs, 30 VDC, 3A max |
| Configuration | 3 isolated, independent groups with 2 outputs per group. Each group shares one common contact. |
| Type | Relays (contact configuration: SPST-NO) |
| Isolation | 550 VAC, 1min |
| Analog IO | |
| Analog input channels |
4 |
| Input type | 0-10V or 4-20mA |
| Input impedance | According to EN 61131-2 |
| Galvanic isolation |
No |
| Resolution | 14 Bit (0-10V: 0…16383 / 4-20mA: 3277…16383) |
| Conversion time | 100ms per channel |
| Accuracy | 0.3% |
| Analog output channels |
2 |
| Output type | 0-10V or 4-20mA |
| Output impedance | According to EN 61131-2 |
| Galvanic isolation |
No |
| Resolution | 14 Bit (0-10V: 0…16383/4-20mA: 3277…16383) |
| Conversion time | 100ms |
| Accuracy | 0.3% |
| Serial communication | |
| Number of serial ports | 2 Port 9pin DSUB |
| Serial port 1 | RS 232 (RTS/CTS) |
| Serial port 2 | RS422/485 |
| Serial port 3 | RS 232 |
| Serial port 4 | RS 485 |
| Ethernet communication | |
| Number of Ethernet ports |
1 |
| Ethernet port 1 | 1x10/100 Base-T (shielded RJ45) |
| Expansion interface | |
| Expansion port | No |
| SD card |
No |
| USB | 1xUSB 2.0 400mA |
| Environmental | |
| Operating temperature | -10°C to +50°C |
| Storage temperature | -20° to +60°C |
| Shock | 15g, half-sine, 11ms according to IEC60068-2-27 |
| Vibration | 1g, according to IEC 60068-2-6, Test Fc |
| Sealing front | IP65 |
| Sealing back | IP20 |
| Humidity | 5% – 85% non-condensed |
| Doküman Adı |
Dil |
|---|---|
| CAB103_10m | |
| CAB103_15m | |
| CAB103_3m | |
| CAB100 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel | |
| CAB101 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel | |
| CAB104 Cable Drawing forX2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel | |
| CAB105 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel | |
| CAB106 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel | |
| CAB107, 25-pol to 9-pol adapter, Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel | |
| CAB108 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel | |
| CAB109 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel | |
| CAB110 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel | |
| AB150 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel | |
| Cable CAB113: Cable for ModBus RS485 between X2 panel and BFI |
| Doküman Adı |
Dil |
|---|---|
| TxA, X2 base image 1.12 b1335 (Current version) | |
| TxA, X2 base image 1.12 b1335 (Current version) (PIEN281H) | |
| TxA, X2 base image 1.12 b1335 (Current version) (PIEN284H) |
| Doküman Adı |
Dil |
|---|---|
| Battery test summary - X2 base, Y2 base v2, BoX2 base v2, C2 industrial PCs | |
| Environmental Report X2 base | |
| X2 export control and dual use | |
| X2 Letter of Volatility | |
| Input regarding unsuported Drivers for X2 base (v1)/BoX2 base (v1) | |
| Guidelines for TxA and TxB migration to X2. |
| Doküman Adı |
Dil |
|---|---|
| 16--TtM_beijer_electronics_life_cycle_notification--X2 base and X2 base ADP | |
| 17--TtL_beijer_electronics_life_cycle_notification--X2-base_image_ADP |
| Doküman Adı |
Dil |
|---|---|
| iX Developer SP7 - 2.47.473 Release information (LastMinuteNotes iX PIEN341L) | |
| iX Developer SP7 - 2.47.473 Release information (ReleaseNotes iX PIEN340Q) | |
| Best Practice Database on SD card or flash memory | |
| How to download Free software packages from SmartStore | |
| iX - SMTP - Using Gmail servers using App password | |
| Quick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411 |
| Doküman Adı |
Dil |
|---|---|
| X2 base 10_Verification FCC | |
| X2 base 5_Verification FCC | |
| X2 base 7_Verification FCC | |
| X2 base 10 – F2_CE Verification | |
| X2 base 5 - F2_CE Verification | |
| X2 base 7 – F2_CE Verification.pdf | |
| X2 base 10 KCC MSIP Certificate | |
| X2 base 10 KCC Permissive letter | |
| X2 base 5 KCC MSIP Certificate | |
| X2 base 5 KCC Permissive letter | |
| X2 base 7 KCC MSIP Certificate | |
| X2 base 7 KCC Permissive letter.pdf | |
| DoC battery X2 base (V2) | |
| DoC ECCN for X2 series HMI | |
| Environmental Impact Report X2 pro, X2 marine, X2 control, X2 motion | |
| RoHS and REACH Declaration of Conformity | |
| UL E192000 for X2Base ,TxA, Exter | |
| X2 base DoC CE ROHS | |
| SDoC Green Passport |
| Doküman Adı |
Dil |
|---|---|
| Program example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3. | |
| Program example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3. | |
| Program example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3. | |
| Quick start guide - Connect X2 HMI with Nexto PLC, SUEN00414 | |
| Quick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406 | |
| Quick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405 | |
| Quick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403 |
| Doküman Adı |
Dil |
|---|---|
| iX Developer Reference Manual, MAEN355 rev. B (current version) |
| Doküman Adı |
Dil |
|---|---|
| Remote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels | |
| SqlProxy - Connects iX Panels transparently to SQL Server (161202C) | |
| SqlProxy - Connects iX Panels transparently to SQL Server (190115) | |
| SqlProxy - Connects iX Panels transparently to SQL Server (191016C) | |
| SqlProxy - Connects iX Panels transparently to SQL Server (170330) |