The X2 base 5 HMI is a cost-effective industrial HMI with high-resolution 5 inch touch-screen and modern design. The X2 base 5 combines IP65 corrosion resistant plastic housing with the full version of the iX software, providing a cost-effective yet advanced HMI solution for small to medium applications.

  • 800 × 480 pixel (16:9)
  • TFT-LCD touch screen
  • 200 MB application memory
  • 1 × Ethernet, 4 × serial, 1 × USB as standard
  • Operating temperature -10° to +50° C
  • CE, FCC, KCC, UL approvals


Facts

General description
Part number 630005105
Life cycle status Mature
Warranty Up to 2 years
Certifications
General CE, FCC, KCC, UL 61010-2-201
Mechanical
Mechanical size

170 x 107 x 49mm

Panel Mount

1million finger touch operations

Touch type Resistive
Cut-out size

161 x 93 mm

Weight

0.5 kg

Housing material Plastic (PC+ABS), Gray
Buzzer

Yes

LED

Yes

Power
Input voltage 24 V DC (18 to 32 VDC)CE: The power supply must conformwith the requirements according to IEC 60950 and IEC 61558-2-4.UL and cUL: The power supplymust conformwith the requirements for class II power supplies.
Power consumption (max) 6W
Input fuse Internal DC fuse
Hardware platform

X2 base

CPU ARM9 400 MHz
RAM

128 MB

FLASH

256 MB, 200 MB free

Display
Size diagonal 5" diagonal
Resolution 800x480 pixels
Backlight LED Backlight
Backlight life time

20000 hours

Backlight brightness 300 cd/m2
Backlight dimming Industrial Dimming
Display type TFT-LCD with LED backlight
Serial communication
Number of serial ports 2 Port 9pin DSUB
Serial port 1 RS 232 (RTS/CTS)
Serial port 2 RS422/485
Serial port 3 RS 232
Serial port 4 RS 485
Ethernet communication
Number of Ethernet ports

1

Ethernet port 1 1x10/100 Base-T (shielded RJ45)
Expansion interface
Expansion port

No

SD card

No

USB 1xUSB 2.0 400mA
Environmental
Operating temperature -10°C to +50°C
Storage temperature -20° to +60°C
Shock 15g, half-sine, 11ms according to IEC60068-2-27
Vibration 1g, according to IEC 60068-2-6, Test Fc
Sealing front IP65, NEMA 4X/ 12 and UL Type 4X/ 12
Sealing back IP20
Humidity 5% – 85% non-condensed
TECHNICAL RESOURCES

The information you need. Within reach.

Check the current manufacturer revision and the conditions applicable to your application.

View documentation (82)
iX Developer SP7 - 2.47.473 Release information (LastMinuteNotes iX PIEN341L) — ENiX Developer SP7 - 2.47.473 Release information (ReleaseNotes iX PIEN340Q) — ENBest Practice Database on SD card or flash memory — ENHow to download Free software packages from SmartStore — ENiX - SMTP - Using Gmail servers using App password — ENQuick start guide, Disable / Suppress Flashwear warning dialogue on X2 series SUEN00411 — ENProgram example iX Developer: Modbus RTU communication between any X2 and BFI-E3, BFI-P2 or BFI-H3. — ENProgram example iX Developer: Modbus TCP communication between any X2 and BFI-P2/H3. — ENProgram example iX Developer: Modbus TCP communication between any X2 HMI and BFI-E3. — ENQuick start guide - Connect X2 HMI with Nexto PLC, SUEN00414 — ENQuick Start Guide, MELSEC iQ-R Ethernet - X2 series SUEN00406 — ENQuick Start Guide, MELSEC Qnn QJ71E71 Ethernet to X2 series SUEN405 — ENQuick Start Guide, MELSEC QnUDE Ethernet to X2 series, SUEN00403 — EN30--EOL_beijer_electronics_life_cycle_notification--X2 base — ENBattery test summary - X2 base, Y2 base v2, BoX2 base v2, C2 industrial PCs — ENEnvironmental Report X2 base — ENX2 export control and dual use — ENX2 Letter of Volatility — ENInput regarding unsuported Drivers for X2 base (v1)/BoX2 base (v1) — ENGuidelines for TxA and TxB migration to X2. — ENGuidelines for TxA and TxB migration to X2. — .pptxX2 base 10_Verification FCC — ENX2 base 5_Verification FCC — ENX2 base 7_Verification FCC — ENX2 base 10 – F2_CE Verification — ENX2 base 5 - F2_CE Verification — ENX2 base 7 – F2_CE Verification — ENX2 base 10 KCC MSIP Certificate — ENX2 base 10 KCC Permissive letter — ENX2 base 5 KCC MSIP Certificate — ENX2 base 5 KCC Permissive letter — ENX2 base 7 KCC MSIP Certificate — ENX2 base 7 KCC Permissive letter — ENDoC battery X2 base (V2) — ENDoC ECCN for X2 series HMI — ENEnvironmental Impact Report X2 pro, X2 marine, X2 control, X2 motion — ENRoHS and REACH Declaration of Conformity — ENUL E192000 for X2Base ,TxA, Exter — ENX2 base DoC CE ROHS — EN​SDoC Green Passport — ENCAB103 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C (CAB103_10m) — ENCAB103 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C (CAB103_15m) — ENCAB103 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C (CAB103_3m) — ENOutline drawing, X2 base 5 — .dwgOutline drawing, X2 base 5 — ENCAB100 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel — ENCAB101 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel — ENAB104 Cable Drawing forX2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel — ENCAB105 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel — ENCAB106 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel — ENCAB107, 25-pol to 9-pol adapter, Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel — ENCAB108 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel — ENCAB109 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C iX operator panel — ENCAB110 Cable Drawing for X2 pro, X2 marine, X2 control, X2 motion, iX Panel TxA/B/C operator panel — ENCAB150 Cable Drawing for X2 base, X2 pro, X2 marine, X2 control, iX Panel TxA/B/C operator panel — ENCable CAB113: Cable for ModBus RS485 between X2 panel and BFI — ENCutout drawing, X2 base 5 — ENiX Developer Reference Manual, MAEN355 rev. B (current version) — ENInstallation Manual, MAxx180 revision B (X2_base_5_MABP180A_pt-br) — PT-BRInstallation Manual, MAxx180 revision B (X2_base_5_MACN180A_cn) — CNInstallation Manual, MAxx180 revision B (X2_base_5_MADE180A_German) — DEInstallation Manual, MAxx180 revision B (X2_base_5_MAEN180A_English) — ENInstallation Manual, MAxx180 revision B (X2_base_5_MAES180A_Spanish) — ESInstallation Manual, MAxx180 revision B (X2_base_5_MAFR180A_French) — FRInstallation Manual, MAxx180 revision B (X2_base_5_MAIT180A_Italian) — ITInstallation Manual, MAxx180 revision B (X2_base_5_MATW180A_tw) — TWRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — ENRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — .exeRemote Access Viewer v1.5.4, for Exter/E1000 - TxA/TxB/TAxx - X2 panels — .zipSqlProxy - Connects iX Panels transparently to SQL Server (161202C) — ENSqlProxy - Connects iX Panels transparently to SQL Server (190115) — ENSqlProxy - Connects iX Panels transparently to SQL Server (191016C) — .zipSqlProxy - Connects iX Panels transparently to SQL Server (170330) — ENX2 brochure (English), BREN631 — ENX2 brochure (Spanish)​ — ESX2 brochure 2019 (French) — FRX2 series (German) — DETxA, X2 base image 1.12 b1335 (Current version) — .exeTxA, X2 base image 1.12 b1335 (Current version) (PIEN281H) — ENTxA, X2 base image 1.12 b1335 (Current version) (PIEN284H) — EN16--TtM_beijer_electronics_life_cycle_notification--X2 base and X2 base ADP — EN17--TtL_beijer_electronics_life_cycle_notification--X2-base_image_ADP — EN
EXPLORE THE PORTFOLIO

Related products

WhatsApp
GET IN TOUCH

Let us call you.

Leave your number and let’s discuss what you need.

Your privacy choices

We use technologies needed to operate the website securely. Analytics and advertising tracking are disabled by default.

No analytics service is currently configured.