Your engineering partner in industrial automation
[email protected]+90 546 425 20 69
Lenze i950 Cabinet Servo Inverter
Lenze

Lenze i950 Cabinet Servo Inverter

The intelligent i950 cabinet servo inverter can be easily integrated into modular machine solutions on the basis of prepared technology applications - parameterization instead of programming

Application-specific product selectionEngineering and technical consulting
Request a product quotationTalk to our team · +90 546 425 20 69

The intelligent i950 cabinet servo inverter can be easily integrated into modular machine solutions on the basis of prepared technology applications - parameterization instead of programming.

The same architecture, the same engineering and the use of the same application software, based on decades of application experience, dissolve the boundaries between centralized and decentralized motion control. Our FAST Application Software Toolbox becomes universally usable. If required, the pre-designed software modules can be very easily customized and extended.

In addition, the i950 cabinet servo inverter serves as a power extension of the i750 cabinet servo inverter in the Lenze automation system in the range from 22 to 110 kW.

The requirements of the Ecodesign Directive, Standard EN IEC 61800-9-2, are met.

Highlights

  • Prepared technology applications, e.g. table positioning, electronic gearbox, winder
  • One Cable Technology (OCT)
  • Modular scalability for feedback system and fieldbus connections
  • Autotuning function for quick and easy controller adjustment
  • Integrated safety technology with a wide range of functions, complies with up to SIL 3/PL e Cat. 4


Technical data and features

Technical data

0.37 ... 110 kW

Connections

1 AC 230 V
3 AC 230 V
3 AC 400 V
3 AC 480 V
4x digital input
1x digital output
1x analog input
Safe inputs for the connection of safety sensors
Safe outputs for safe feedback
DC bus
Motor temperature monitoring
Resolver/multi-encoder input for feedback (motor)
Resolver/multi-encoder input for feedback (load)
One Cable Technology (OCT) via HIPERFACE DSL®
Connection of safety-rated encoder systems

Communication

EtherCAT
Ethernet
EtherNet/IP
PROFINET
Safety bus FSoE
PROFIsafe safety bus on PROFINET
Operation with safety PLC

TECHNICAL RESOURCES

The information you need. Within reach.

Check the current manufacturer revision and the conditions applicable to your application.

View documentation (87)
i950 cabinet servo inverter — ENi950 cabinet servo inverter — CSi950 cabinet servo inverter — DEi950 cabinet servo inverter — ESi950 cabinet servo inverter — FRi950 cabinet servo inverter — HUi950 cabinet servo inverter — ITi950 cabinet servo inverter — PLi950 cabinet servo inverter — PTi950 cabinet servo inverter — RUi950 cabinet servo inverter — USi950 cabinet servo inverter — ZHServo inverters — ENServo inverters — DEAccessories — ENAccessories — CSAccessories — DEAccessories — ESAccessories — FRAccessories — HUAccessories — ITAccessories — PLAccessories — PTAccessories — RUAccessories — SKAccessories — ZHi950 cabinet servo inverter — ENi950 cabinet servo inverter — DEi950 cabinet servo inverter — ENi950 cabinet servo inverter — DE"CiA 402 advanced" technology application — EN"CiA 402 advanced" technology application — DE"Speed Control" technology application — EN"Speed Control" technology application — DE"Table Positioning" technology application — EN"Table Positioning" technology application — DE"Electronic Gearbox" technology application — EN"Electronic Gearbox" technology application — DE"Sync and Correction" technology application — EN"Sync and Correction" technology application — DE"Winder Dancer" technology application — EN"Winder Dancer" technology application — DE"Winder Tension" technology application — EN"Winder Tension" technology application — DEFunctional safety — ENFunctional safety — DECE (European Union) — ENCE (European Union), Basic Safety — ENCE (European Union), Extended Safety — ENUKCA (United Kingdom), Basic Safety — ENUKCA (United Kingdom), Extended Safety — ENUL, DOE (USA) — ENCCC (China) — ENCE (European Union), Basic Safety — ENCE (European Union), Basic Safety, Revision List — ENCE (European Union), Extended Safety — ENCE (European Union), Extended Safety, Revision List — ENUKCA (United Kingdom), Basic Safety — ENUKCA (United Kingdom), Basic Safety, Revision List — ENUKCA (United Kingdom), Extended Safety — ENUKCA (United Kingdom), Extended Safety, Revision List — ENInverters - Power losses according to Ecodesign Directive — ENInverters - Power losses according to Ecodesign Directive — CSInverters - Power losses according to Ecodesign Directive — DEInverters - Power losses according to Ecodesign Directive — ESInverters - Power losses according to Ecodesign Directive — FRInverters - Power losses according to Ecodesign Directive — HUInverters - Power losses according to Ecodesign Directive — ITInverters - Power losses according to Ecodesign Directive — PLInverters - Power losses according to Ecodesign Directive — PTInverters - Power losses according to Ecodesign Directive — RUInverters - Power losses according to Ecodesign Directive — ZHSISTEMA library — ENCertificate ISO 9001 : 2015 — ENCertificate ISO 9001 : 2015 — DECertificate ISO 14001 : 2015 — ENCertificate ISO 14001 : 2015 — DECertificate ISO 22301 : 2019 — ENCertificate ISO 22301 : 2019 — DECertificate ISO 27001 : 2017 — ENCertificate ISO 27001 : 2017 — DECertificate ISO 37301 : 2021 — ENCertificate ISO 37301 : 2021 — DECertificate ISO 50001 : 2018 — ENCertificate ISO 50001 : 2018 — DEREACH declaration — ENPWIS-free — EN
EXPLORE THE PORTFOLIO

Related products

WhatsApp
GET IN TOUCH

Let us call you.

Leave your number and let’s discuss what you need.

Your privacy choices

We use technologies needed to operate the website securely. Analytics and advertising tracking are disabled by default.

No analytics service is currently configured.